Short answer: Somfy AC RS485 motors such as the Sonesse 506S2 RS485 take a 4-conductor 26 AWG RJ9 to RJ45 data cable. Grey cables (9018545 to 9018548) carry the motor's 7.5 V power out to a module. Black cables (9018541 to 9018544) carry data only and are the animeo IP choice. Keep the drop inside 10 m.
A shade goes quiet on an SDN job. The tech swaps the patch cable from the van, the motor still ignores the bus, and the callback turns into a second trip. The fix costs less than lunch. The mistake is grabbing any RJ cable that fits. This guide covers the replace and re-drop case for Somfy 120V RS485 motors.
Free spec package
Somfy AC RS485 motor data cable retrofit drawing set

- Cable schedule: refs, lengths, jacket, power out
- Bus riser with RJ9 drops and 120 ohm terminators
- RJ9 and RJ45 pinout schedules
- Retrofit checklist and 3-part guide spec
Two cable families, one plug pattern
Somfy builds the motor data cable as a 4-conductor 26 AWG modular cable with an RJ9 plug at the motor and an RJ45 plug at the network. Somfy sells it in two jackets and four lengths. The grey family carries power out: 2.5 ft 9018545, 8 ft 9018546, 12 ft 9018547 and 24 ft 9018548. The black family carries data only: 2.5 ft 9018541, 8 ft 9018542, 12 ft 9018543 and the 24 ft 9018544.
The plugs match, so both cables click into the same motor. That is the trap. The difference lives on one pin, and a module at the far end that expects power gets nothing from a black cable.
Somfy motors that take these cables
Somfy lists five 120V RS485 motors against both cable families: the Sonesse 506S2 RS485 (1002286), the Sonesse 510S2 RS485 (1002287), the Sonesse ULTRA 506A2 RS485 (1002566), the 515S2 RS485 (1002427) and the 535A2 RS485 (1002288). Line voltage stays on the motor power cord; the data cable carries RS485 and low-voltage power out only.
Somfy publishes the 506S2 at 6 Nm, 32 rpm, 1.2 A and 45 dBA, and the 510S2 at 10 Nm, 32 rpm, 1.66 A and 47 dBA. The ULTRA 506A2 runs 6 Nm at 24 rpm, 0.95 A and 38 dBA, rated IP 31 for interior use. All three need a tube ID over 47 mm and come with a 9.8 ft 3-conductor SJTW power cord that Somfy allows to be wired in parallel per NEC and local code.
The 24V DC Sonesse 30 RS485 (1241144) is a different animal. It lands on the 5-conductor SDN power and data cable 9020126, and Somfy does not list it for the RJ9 cables.
Read the pinout before you order
Somfy's Sonesse 50 and LT50 RS485 instructions (ref. 5106220A) print the pinout. At the RJ9 end: pin 1 RS485+, pin 2 RS485-, pin 3 power out, pin 4 ground. At the RJ45 end: pin 1 RS485+, pin 2 RS485-, pin 4 power out, pin 8 ground, with 3, 5, 6 and 7 unused. Power out is 7.5 V at 30 mA max.
Thirty milliamps is a small budget. Our rule: treat the grey conductor as a courtesy feed for one module at the motor, never as bus power for anything else on the segment.
Somfy RJ9 to RJ45 data cable: hard numbers
- 4 conductors, 26 AWG, RJ9 at the motor, RJ45 at the network
- Lengths: 2.5, 8, 12 and 24 ft in both jackets
- Grey power out: 7.5 V, 30 mA max (RJ9 pin 3, RJ45 pin 4)
- Data cable from bus to motor: 10 m max
- SDN segment ends: 120 ohm, 0.3 W terminator
- Warranty on the cable: 5 years
Grey or black: let the far end decide
Somfy's spec sheets D-0023 and D-0024 spell out the split. Black has no power out and is the cable for animeo IP networks. Grey has power out and exists to power external modules. Somfy lists RTS, Z-Wave and Zigbee modules, plus SDN and animeo IP networks, as uses for this cable.
On a retrofit you inherit the original designer's choice. Our rule: match the jacket color you pull out, and label the new drop at both ends with the motor's node ID and color. A black drop on an animeo IP facade stays black. A grey drop feeding a module stays grey. If the drawings say nothing, open the far end and look before you order.
Length: stay inside 10 meters
Somfy's instructions cap the data cable between the RS485 bus wire and the motor at 10 m, about 33 ft. The longest stock cable is 24 ft, so a stock drop leaves room for slack. Somfy also offers custom lengths.
The common retrofit failure is a field splice: an old drop extended with a coupler and a second patch cable to reach a relocated pocket. Our rule: if the motor sits more than 24 ft from the bus, move the bus tap toward the motor instead of stacking cables. Each coupler is one more joint to fail on a callback.
Swap, test and re-check the motor
Cut power to the shade first; Somfy's service warning covers any work near the motor. Pull the old cable, seat the new one until both latches click, and restore power. Then plug the RS485 Setting Tool 9017142 into the motor. Somfy's tool menu runs node discovery, motor rotation, up and down limits, and presets 1 to 16, so you can read the node ID and confirm limits before the bus sees the motor again.
For the bus side, Set pro on a laptop through the USB to RS485 adaptor 9015260 rediscovers the node so the control system finds the same address. Somfy's troubleshooting table tells you to check the data cable when an RS485 motor runs noisy and lists a wrong data cable as a cause, so a cable check belongs early in the fault tree, ahead of replacing the motor.
Order the right quantity
Count drops by length band, then by jacket. Measure each from the bus tap to the motor head, add slack, and round up to the next stock length: 2.5, 8, 12 or 24 ft. Our rule: order one spare per jacket per floor. A spare costs less than the truck roll it prevents.
Somfy prints a 5-year warranty on these cables. Keep the motor ref, cable ref and node ID together on the as-built so the next tech skips the guessing.
Take the spec package to your submittal
Somfy AC RS485 motor data cable retrofit drawing set
- 4 ANSI A sheets: general, physical, riser and wiring, specifications
- Editable guide spec items in brackets
FAQ
Can I use a standard Ethernet patch cable on a Somfy RS485 motor?
No. The motor port is RJ9, and Somfy specifies a 4-conductor 26 AWG RJ9 to RJ45 cable with a fixed pinout. Order the grey 9018545 to 9018548 or black 9018541 to 9018544 family.
What does the grey Somfy RS485 data cable power?
The grey cable carries the motor's power out on RJ9 pin 3 and RJ45 pin 4, rated 7.5 V at 30 mA max. Somfy uses it to power external modules such as RTS, Z-Wave or Zigbee modules.
How long can the data cable be from the bus to the motor?
Somfy's Sonesse 50 and LT50 RS485 instructions cap it at 10 m, about 33 ft. Stock lengths are 2.5, 8, 12 and 24 ft.
Does the Sonesse 30 RS485 use the RJ9 cable?
No. The 24V DC Sonesse 30 RS485 (1241144) connects with the 5-conductor SDN power and data cable 9020126, which carries motor power and data together.
Sources: Somfy Sonesse 50 RS485 spec sheet D-0023 (10/2017); Sonesse ULTRA 50 RS485 spec sheet D-0024 (10/2017); Sonesse 50 RS485 / LT50 RS485 installation guide ref. 5106220A; Somfy SDN Reference Book; somfysystems.com product pages 9018545, 9018541, 1002286 and 9020126.
Ryan Towns writes the Somfy Integrator Guides for ShadeMotorsDirect, an authorized Somfy distributor. Questions on a spec or a retrofit: 859-414-6872 or colin@shademotorsdirect.com, 8:00 AM - 7:30 PM ET.