Short answer: Somfy builds five 120V RS485 motors for SDN shades: Sonesse ULTRA 50 at 6 Nm and 38 dBA, Sonesse 50 at 6 or 10 Nm, and LT50 at 15 or 35 Nm. Pick by torque first, then by the dBA line. Hold the tube ID over 47 mm, order the grey data cable separately and land each motor on a Data Hub V2 port.
Line-voltage SDN shades fail in two places. The motor ships without its data cable and the crew finds out on the ladder. Or a 55 dBA motor lands in a boardroom that was promised quiet. Both cost a return trip. This guide puts the numbers for all five motors on one page so the schedule gets them right the first time.
Free spec package
Somfy 500 Series RS485 motor drawing set

- SMD-01 motor schedule and system limits with a source per number
- SMD-02 head face, published L1/L2/L3 lengths, motor-in-tube detail
- SMD-03 SDN riser, RJ9 and RJ45 pinouts, data cable schedule
- SMD-04 three-part guide spec, BOM and submittal checklist
Pick the motor by torque, then by the dBA line
Somfy publishes every rating on three spec sheets. On the 6 and 10 Nm end, Sonesse 50 506S2 RS485 (1002286) runs 6 Nm at 32 rpm and 45 dBA. Sonesse 50 510S2 RS485 (1002287) runs 10 Nm at 32 rpm and 47 dBA. For a quiet room, Sonesse ULTRA 50 506A2 RS485 (1002566) delivers 6 Nm at 24 rpm and 38 dBA.
Big shades go to the LT50 RS485 pair. LT50 515S2 RS485 (1002427) gives 15 Nm at 38 rpm. LT50 535A2 RS485 (1002288) gives 35 Nm at 20 rpm. Somfy rates both at 55 dBA.
Our rule: write the torque and the dBA number into the shade schedule, per shade. A 38 dBA line points at ULTRA 50. Anything over 10 Nm points at LT50, and the room accepts 55 dBA. Sonesse ULTRA 50 also lists a 0.4 Nm minimum torque, the minimum application weight for smooth operation. Keep shades lighter than that off it.
Tube and hardware rules that keep a 50 mm motor quiet
All five spec sheets carry the same fabrication rules. The tube inside diameter must be greater than 47 mm. Every motor needs a crown adaptor for concentric operation. Somfy recommends the 500 Series drive stop and screw (9910004), tightened between 1.5 and 1.8 Nm, to stop noise and drive wheel separation.
Two more lines go into the fabricator notes. Somfy does not recommend the brown soft clip drive wheel adaptors. On Sonesse ULTRA 50, Somfy recommends screwing the drive wheel and pin end to the tube to hold the quiet rating over the life of the shade.
The star head fixes to its bracket with two self tapping screws, 5 mm diameter and 13 mm deep, spaced 48 mm (1.89 in) apart. Somfy lists the Sonesse 50 star head motor bracket 55P (9014135) for Sonesse 50 and the LT50 universal motor bracket (9410651), rated 50 Nm maximum, which covers the 35 Nm LT50.
Hard numbers for a 500 Series RS485 schedule
- Tube inside diameter greater than 47 mm, crown adaptor on every motor.
- Drive stop 9910004 tightened to 1.5 to 1.8 Nm.
- Electronic limits with 300 turns capacity, 4 minute thermal protection.
- Power: 120V AC 60 Hz on a 9.8 ft (3 m) 3-conductor SJTW cable.
- Data: 4-conductor 26 AWG RJ9 to RJ45 cable, ordered separately.
- Data Hub V2 stubs up to 200 ft per device port.
- 2000 ft maximum bus wiring per bus power source.
Two cables per motor: 120V power and the RS485 drop
Each motor ships with a 9.8 ft SJTW power cable: black hot, white neutral, green ground. Somfy allows parallel wiring of the 120V supply in accordance with NEC and local electrical codes. Show a circuit and a box at every headbox on the electrical drawings.
The data cable must be ordered separately, and the color matters. The grey cable carries power out on RJ9 pin 3 for external modules and is the one Somfy shows at the Data Hub V2. Order it as the grey RJ9 to RJ45 data cable, 2.5 ft (9018545) or the 8 ft grey cable (9018546). The black data only cable, such as the 2.5 ft black cable (9018541), is the animeo IP version.
The pinout is short. At the RJ9 on the motor: pin 1 + RS485, pin 2 - RS485, pin 3 power out, pin 4 ground. At the RJ45: pin 1 + RS485, pin 2 - RS485, pin 8 ground.
Interior, exterior and temperature limits
Sonesse 50 RS485 and LT50 RS485 carry IP 44 for interior and exterior use. Sonesse 50 RS485 works from -4 to 158 F. LT50 RS485 works from -4 to 140 F. Sonesse ULTRA 50 RS485 is IP 31, interior only, rated 32 to 140 F.
An exterior solar screen on SDN therefore gets a Sonesse 50 or LT50 RS485. Keep ULTRA 50 inside the glass.
Landing the motors on the SDN bus
The SDN Data Hub V2 (1870951) adds five device ports to the bus line, each with a stub up to 200 ft. Somfy states it runs on motor power once two or more motors connect to its device ports. Keep each bus power source within 2000 ft of bus wiring and each segment to 40 bus distribution devices.
Third-party control lands through the Somfy Connect UAI Plus (1870272) for Control4, Crestron or Savant. Budget bus power before you add keypads and interfaces.
Commissioning: limits first, then addresses and groups
Somfy sets 500 Series RS485 limits with the RS485 Setting Tool (9017142). Plug it into the motor, power up and follow the tool. Addressing and grouping run in Set pro by Somfy through the USB to RS485 adaptor (9015260).
Our rule: set limits on the bench or at the bracket before the bus goes live, then label each shade with its motor address on the as-built.
Take the spec package to your submittal
Somfy 500 Series RS485 motor drawing set
- SMD-01 motor schedule and system limits with a source per number
- SMD-02 head face, published L1/L2/L3 lengths, motor-in-tube detail
- SMD-03 SDN riser, RJ9 and RJ45 pinouts, data cable schedule
- SMD-04 three-part guide spec, BOM and submittal checklist
FAQ
Which Somfy RS485 motor is the quietest on 120V?
Sonesse ULTRA 50 506A2 RS485 (1002566) is rated 38 dBA at 6 Nm and 24 rpm. It is interior only, IP 31, and needs a tube ID over 47 mm.
Does a Sonesse 50 RS485 motor come with a data cable?
No. Somfy ships the motor with a 9.8 ft SJTW power cable. The 4-conductor 26 AWG RJ9 to RJ45 data cable is ordered separately, grey with power out or black data only.
Can Sonesse 50 RS485 motors run on an exterior screen?
Yes. Sonesse 50 RS485 and LT50 RS485 carry IP 44 for interior and exterior use. Sonesse ULTRA 50 RS485 is IP 31 and interior only.
How far can an RS485 motor sit from the Data Hub V2?
Somfy rates Data Hub V2 device stubs up to 200 ft per port. The bus itself stays within 2000 ft of wiring per bus power source.
Sources: Somfy Sonesse 50 RS485 spec sheet D-0023, Sonesse ULTRA 50 RS485 spec sheet D-0024 and LT50 RS485 spec sheet D-0034 (10/2017, service.somfy.com); somfysystems.com product pages 1002287, 1002288, 1002427, 1870951 and 9017142; SDN Data Hub V2 spec sheet and instructions; Sonesse 50 RS485 installation instructions (RS485 Setting Tool).
Ryan Towns writes the Somfy Integrator Guides for ShadeMotorsDirect, an authorized Somfy distributor. Questions on a spec or a retrofit: 859-414-6872 or colin@shademotorsdirect.com, 8:00 AM - 7:30 PM ET.