Skip to content
Genuine Somfy Motors & Parts for Roller Shades
Altus RTS

Replace a Failed Somfy LT60 Altus RTS Motor on a Large Awning

Short answer: Read the old label, then order the LT60 Altus RTS with the same torque: 660R2 (60 Nm), 680R2 (80 Nm) or 6100R2 (100 Nm). Check the rivet line, the LT60 crown and drive, the bracket rating and 12 in of free antenna cord. Then set limits and re-pair every remote and sensor.

A failed LT60 on a 20 ft awning is a two-person job with a lift. Get one number wrong and you pay for that lift twice. The usual miss is a motor that fits the tube but drills to the wrong rivet line, or a 100 Nm motor hanging on a spring ring rated for 80 Nm. This guide gives you the checks in order, with every value from Somfy's own documents.

Free spec package

LT60 Altus RTS replacement drawing set

ShadeMotorsDirect spec package drawing set, sheet SMD-01
  • Sheet SMD-01: retrofit notes and LT60 limits schedule
  • Sheet SMD-02: dimensioned motor detail, crown and drive schedule
  • Sheet SMD-03: 120 V wiring, RTS control riser, programming sequence
  • Sheet SMD-04: 3-part guide spec, bill of materials, retrofit checklist
Download the PDF drawing set (4 sheets)Written and drawn by ShadeMotorsDirect. Free, no email required.

Read the label before you order anything

Somfy prints the whole spec in the model code. In the 600 Series Databook key, the first digit is the motor diameter, so 6 means LT60. The next digits are torque in newton meters. R means the rolling shutter speed of 14 rpm, and 2 means the 120 V range. A 680R2 label tells you LT60, 80 Nm, 14 rpm, 120 V before you open a catalog.

The 2014 databook lists the LT60 Altus RTS family as 1162213, 1164132 and 1166142 with a 6.5 ft cord. Somfy's current US references carry a 10 ft white SJTW cord: Altus RTS 660R2 1162271, Altus RTS 680R2 1164261 and Altus RTS 6100R2 1166289. Same torque, same 14 rpm, same 200-turn electronic limit switch. Order the current reference and keep the old label photo in the job file.

RETROFIT DETAILFour checks before you order theLT60 replacementSomfy LT60 Altus RTS 660R2 motor 1162271Label code660R2 = LT60, 60 Nm,14 rpm, 120 VRivet line (L2)26.65 in on 660R2.28.23 in on 680R2 and6100R2.Antenna cord12 in minimum, neveragainst metalTube and drive2.37 in minimum ID.LT60 crown only.ShadeMotorsDirect.com
LT60 Altus RTS 660R2 (1162271). Values from the Somfy 600 Series Databook and the Somfy e-catalog.

Match torque and current, never guess down

All three motors run at 14 rpm on 120 V, 60 Hz. Torque and current climb together: 60 Nm at 2.5 A, 80 Nm at 3.4 A, 100 Nm at 3.8 A. Each one has a 4 minute thermal protection time and a 200-turn limit capacity, per the databook and the Somfy e-catalog.

Our rule: replace like for like on torque. A smaller motor on a heavy awning trips its thermal cutout and reads as a second failure. If the old motor was undersized and kept overheating, step up one size and treat it as a rework, because the rivet line and bracket may change with it.

LT60 Altus RTS numbers to carry on site

  • Limit switch capacity: 200 turns, electronic, set by radio
  • Thermal protection time: 4 minutes on all three torques
  • Tube: 2.37 in minimum internal diameter
  • Riveting: 4 steel pop rivets or screws, 5 mm diameter, 12 mm long, 90° apart
  • Antenna: built into the power cord, at least 12 in free, no contact with metal
  • Spring ring 9206033 up to 80 Nm. 6100R2 needs locking spring ring 9910002
  • Supply: 120 V, 60 Hz, 108 V to 126 V range

Check the tube, the crown and the drive

The LT60 needs a tube with at least a 2.37 in internal diameter. The crown rides on the motor head end and the drive wheel transmits torque at the rivet line. Both must match the tube profile, and the crown must be an LT60 crown.

Now the rivet line. The 600 Series Databook gives the riveting distance (L2) as 26.65 in (677 mm) on the 660R2 and 28.23 in (717 mm) on the 680R2 and 6100R2. Fasten the tube to the drive with 4 steel pop rivets or screws, 5 mm diameter and 12 mm long, 90° apart. Swap 660R2 for 660R2 and the old holes line up. Upsize to a 680R2 and the holes move 1.58 in.

DECISION DRAWINGMatch torque first, then the rivetline and spring ringSomfy LT60 Altus RTS 660R2 · 1162271Somfy LT60 Altus RTS 680R2 · 1164261Somfy LT60 Altus RTS 6100R2 · 1166289Upsizing 660R2 to 680R2?The rivet line moves 1.58 in (40 mm). Drillnew holes.660R2 · 116227160 Nm (530 in-lb)2.5 AL2 26.65 inSpring ring 9206033680R2 · 116426180 Nm (700 in-lb)3.4 AL2 28.23 inSpring ring 92060336100R2 · 1166289100 Nm (880 in-lb)3.8 AL2 28.23 inLocking ring 9910002ShadeMotorsDirect.com
LT60 Altus RTS ladder from the Somfy 600 Series Databook (L-0210) and e-catalog. Same 14 rpm speed and 200-turn limit capacity on all three.

Rate the bracket and the spring ring for the new motor

The bracket is where an upsized job fails. The universal motor bracket with spring ring 9420631 is rated for 85 Nm. Somfy rates it for 100 Nm only with the locking spring ring 9910002 and 5/16-18 or M8 bolts without the molded nuts, for a maximum system load of 200 kg (441 lb).

The standard spring ring 9206033 is rated for brackets and motors up to 80 Nm. Somfy states the locking spring ring 9910002 must be used with all brackets on the 6100R2, and on any install where the tube flexes more than normal. Secure its locking screw so the motor head cannot walk out of the bracket.

Our rule: on a 6100R2 job, put the locking spring ring on the order before the motor. A 100 Nm head on an 80 Nm ring is a callback waiting for wind.

Wire the 120 V feed and place the antenna

The LT60 Altus RTS takes a 3-conductor cord: white neutral, black hot, green ground. The e-catalog lists a 108 V to 126 V supply range and 0 W in standby. The RTS receiver is built into the motor, so you power it directly and leave the switching to radio.

The antenna lives inside the power cord. The databook requires at least 12 in of that cord, clear of metal. On an awning with a steel front bar or a shutter in an aluminum box, route that 12 in out of the housing before you clip the cord down. Somfy rates the radio at 433.42 MHz with 164 ft range in open field. Metal cuts that number fast.

Set limits and re-pair every control

The new motor has no limits and no paired remotes. Power one motor at a time and follow the Somfy Altus 6 Step Visual Reference Guide (S-0027):

  1. Press UP and DOWN together until the motor jogs.
  2. Hold DOWN. If the product moves up or in, hold MY until the motor jogs to reverse it.
  3. Hold MY and UP until it moves up, then release. Bring it to the upper limit.
  4. Hold MY and DOWN until it moves down, then stop it at the lower limit. On large units, set the lower limit halfway out first.
  5. Hold MY until the motor jogs to confirm the limits.
  6. Hold the program button on the back of the remote until the motor jogs. The motor now runs in maintained mode.

On large units, Somfy tells you to finalize programming, let the motor rest 10 minutes, then adjust to the final outer limit. That rest protects the 4 minute thermal time during a long first run.

Pair the controls next. A Situo 5 RTS Pure 1870575 covers a patio with five zones, and a Telis 16 RTS 1811081 covers a full facade. To add one, press the program button on a paired remote until the motor jogs, then press the program button on the new remote or sensor. Wind protection comes from the Eolis RTS wind sensor kit 9012499 or the Eolis 3D WireFree RTS 1816081. Integrators bring the motor into automation through the TaHoma Switch 1871037 or the URTSI II 1810872.

Picked up a motor someone else already paired? Cut power for 2 seconds, restore it for 10 seconds, cut it for 2 seconds and restore it. Once the motor moves and stops, hold the program button on the remote until it jogs twice. The memory is clear and you start again at step 1.

Take the spec package to your submittal

Take the LT60 retrofit sheets to the job

  • Torque, current and riveting schedule for all three LT60 Altus RTS motors
  • Bracket and spring ring rating table
  • Retrofit checklist and editable 3-part guide spec
Download the PDF drawing set (4 sheets)Written and drawn by ShadeMotorsDirect. Free, no email required.

FAQ

Can I put an LT50 Altus RTS motor in place of a failed LT60?

Order the LT60 reference that matches the torque on the old label: 660R2 (60 Nm), 680R2 (80 Nm) or 6100R2 (100 Nm). The LT50 Altus RTS range tops out at 50 Nm with the 550R2, below every LT60 torque, and the existing crown and bracket are sized for the LT60 head.

Does a new LT60 Altus RTS motor keep the old remote?

No. A new motor ships without limits or paired controls. Program it with one RTS remote, set the limits, then add the other remotes and sensors with the program button. Each motor holds 12 channels.

Is the 6100R2 a drop-in for a 660R2 that keeps tripping?

Only after you rework the tube and bracket. The 6100R2 rivet line sits at 28.23 in instead of 26.65 in, and Somfy requires the locking spring ring 9910002 with every bracket on the 6100R2.

How do I reset an LT60 Altus RTS motor that was paired to the wrong remote?

Cut 120 V power for 2 seconds, restore it for 10 seconds, cut it for 2 seconds and restore it. The motor moves and stops. Hold the program button on the remote until the motor jogs twice, per the Somfy Altus 6 Step Visual Reference Guide.

Sources: Somfy 600 Series Databook L-0210 (service.somfy.com); Somfy e-catalog entries for 1162271, 1164261 and 1166289 (somfypro.com); somfysystems.com product page for Altus RTS 660R2 1162271; Somfy Altus 6 Step Visual Reference Guide S-0027 (11/2013).