Short answer: Read the model code on the failed motor (404S2, 406A2 or 409R2) and order the matching fast connector Sonesse 40 RTS: 1240380, 1240381 or 1240382. Torque, speed and the RTS radio carry over. The cord does not. Plan an extension or panel mount for the 1.6 ft lead, then set limits and pair every control again.
A dead Sonesse 40 RTS costs you one service call. The cord costs you the second. The old hardwired motor left the head with 11.5 ft of cable; the fast connector version leaves with 1.6 ft. Show up without the right extension and the shade sits in the van until next week.
Free spec package
Sonesse 40 RTS fast connector retrofit drawing set

- SMD-01 general notes and Sonesse 40 RTS limits schedule
- SMD-02 head mounting detail, length schedule and tube hardware
- SMD-03 power drop riser, conductor and extension schedules
- SMD-04 three-part guide spec, BOM and retrofit checklist
Match the label code before you order
Pull the shade and read the motor label. The code starts with 40 for the 40 mm motor; the next digit is torque in newton meters. Order by that code and the shade keeps its speed and lift.
| Label code | Torque / speed | Hardwired RTS | Fast connector RTS |
|---|---|---|---|
| 404S2 | 4 Nm / 36 rpm | 1001636 | 1240380 |
| 406A2 | 6 Nm / 24 rpm | 1001637 | 1240381 |
| 409R2 | 9 Nm / 14 rpm | 1001638 | 1240382 |
Somfy rates both versions the same: .95 A, 1.2 A and .98 A rated current, 4 minutes of thermal protection, 433.42 MHz RTS radio and 42, 44 and 40 dBA. The fast connector models are Sonesse 40 RTS 404S2 with fast connector 1240380, 406A2 1240381 and 409R2 1240382. Your client keeps the same quiet motor.
Count the conductors before you order. An RTS motor carries 3 conductors: white neutral, black hot, green ground. A Sonesse 40 WT carries 4, with red and black as the two directions, and runs from a wired switch. A WT shade takes a WT replacement such as Sonesse 40 WT 404S2 with fast connector 1240377. Mix them up and the shade never moves.
Hardwired vs fast connector: four differences
Somfy kept the motor core and changed the cable exit. Four numbers move between the 400 Series Databook pages for the two versions:
- Cord. 11.5 ft (3.5 m) 3-conductor cable on the hardwired motor; a 1.6 ft (0.5 m) 3-conductor SJTW lead to a fast connector on the new one.
- Length. L1 grows from 504 mm to 507 mm on the 404S2 and from 535 mm to 538 mm on the 406A2 and 409R2. L2 and L3 grow by the same 3 mm.
- Sealing. The motor stays IP 44 for interior use. The fast connector itself is rated IP55.
- Limit capacity. 250 turns on the hardwired motor, 200 turns on the fast connector motor.
Our rule: one turn of a bare 40 mm tube moves about 4.9 in of fabric, so 200 turns covers more than 80 ft of drop before fabric build-up. The turn cap rarely binds on an interior shade. Check it on a tall projection screen or a long drop on a small tube.
Plan the power drop before the truck rolls
The 1.6 ft lead ends in a male fast connector. Somfy gives you three ways to land it, and the existing power source picks the part.
Receptacle. Use a 3-conductor fast connector extension with a NEMA plug: 1.4 ft 9021113, 4.4 ft 9021114, 8.4 ft 9021115, 10.4 ft 9020791, 18 ft 9020792 or 24 ft 9020793.
Junction box with a splice. Use the 8.4 ft open-lead extension 9021157 and splice it in the box. Junction box without a splice. Mount the panel mount female fast connector 9026398 to the box and plug the motor lead into it.
Our rule: measure the cord route from the motor head to the outlet or box, add the slack you need for service, then order the next length up. A hardwired connection belongs in a listed box, made by a licensed electrician to NFPA 70 and local code.
Keep the antenna clear of metal
The Sonesse 40 RTS has no separate antenna wire. Somfy builds the antenna into the power cord and sets two conditions: the cord must be at least 12 in long, and it must not touch metal. The 1.6 ft lead plus the extension clears the length rule. The metal rule takes discipline.
Old hardwired jobs often hide 11.5 ft of cord coiled inside an aluminum cassette or zip-tied to a steel bracket. Repeat that habit with the new lead and range drops. Our rule: route the first 12 in of cord through open air or along wood or drywall, and tie it off with plastic clips, away from the headrail and the brackets.
Reuse the tube hardware, check two limits
Both motors take the 400 Series crowns and drives Somfy lists in the 400 Series Databook. A sound set comes across: crown and drive set 9012224 for a 40 x 1.5 mm round tube, rubberized set 9016654 for the same tube, rubberized octagonal set 9016655 for a 40 mm octagonal tube, or the 400 to 500 Series adaptor kit 9013763 for 500 Series crowns and drives, rated to 13 Nm.
Two limits catch retrofits. Somfy requires a tube inside diameter of 38 mm or more so the tube never touches the motor body. Somfy also rates the Decorator Type motor and idler brackets to 4 Nm maximum, so a 406A2 or 409R2 needs a different bracket. On rubberized drives, Somfy recommends a silicone lubricant on the drive adaptor and the 400 Series drive stop with screw, 9147894, to keep the drive on the shaft.
The head mounts with 2 self-tapping screws, 4 mm diameter, set 1.14 in (29 mm) apart. Somfy includes the screws with each motor.
Sonesse 40 RTS swap: the numbers
- 404S2 = 4 Nm / 36 rpm, 406A2 = 6 Nm / 24 rpm, 409R2 = 9 Nm / 14 rpm on both versions
- Hardwired cord 11.5 ft (3.5 m); fast connector lead 1.6 ft (0.5 m)
- Limit capacity: 250 turns hardwired, 200 turns fast connector
- Power cord antenna: at least 12 in, never in contact with metal
- Tube inside diameter 38 mm or more; Decorator Type brackets max 4 Nm
- Motor IP 44, interior only; fast connector IP55; 32 to 140 F working range
Program the motor and re-pair every control
Somfy ships every RTS motor in factory mode: no limits, no paired controls. The old motor took its memory with it. Budget time on site for a full program:
- Power the motor alone on its circuit.
- Press and hold UP and DOWN together on the remote until the shade jogs.
- Check direction. If the shade runs backward, hold MY until it jogs to reverse it.
- Set the upper and lower limits, then hold MY until the shade jogs to confirm them.
- Press the PROG button on the back of the remote until the shade jogs. The remote is now paired.
Then pair every other control the old motor answered to: each Situo 5 RTS Pure 1870575 channel, every wall switch, the URTSI II channel your Control4, Crestron or Savant driver calls, and the TaHoma Switch 1871037. Our rule: write the channel map before you pull the old motor, so the new one lands on the same channels and the integration program needs no edits.
Retrofit checklist
- Photograph the motor label and record 404S2, 406A2 or 409R2.
- Confirm 3 conductors (RTS) or 4 (WT).
- Record the power source: receptacle or junction box, and the cord route length.
- Record the crown, drive and bracket type and check the 4 Nm Decorator limit.
- Write the RTS channel map: remotes, wall switches, URTSI II, TaHoma.
- Order the motor, the extension or panel mount and a drive stop for rubberized drives.
Take the spec package to your submittal
Sonesse 40 RTS fast connector retrofit drawing set
- SMD-01 general notes and Sonesse 40 RTS limits schedule
- SMD-02 head mounting detail, length schedule and tube hardware
- SMD-03 power drop riser, conductor and extension schedules
- SMD-04 three-part guide spec, BOM and retrofit checklist
FAQ
Can a fast connector Sonesse 40 RTS replace a hardwired one?
Yes. Match the label code: 404S2 goes to 1240380, 406A2 to 1240381, 409R2 to 1240382. Torque, speed, current and the 433.42 MHz radio match. Plan an extension or panel mount for the 1.6 ft lead.
Do I need to reprogram the new Sonesse 40 RTS motor?
Yes. Somfy ships RTS motors in factory mode with no limits and no paired controls. Set direction and limits, then pair every remote, wall switch, URTSI II channel and TaHoma device again.
Can I reuse the old crown and drive?
Both motors take the 400 Series crowns and drives in Somfy's 400 Series Databook. Reuse an undamaged set that fits a tube with an inside diameter of 38 mm or more, and add the 9147894 drive stop on rubberized drives.
How long can the extension cable be?
Somfy lists 3-conductor fast connector extensions with a NEMA plug in 1.4, 4.4, 8.4, 10.4, 18 and 24 ft lengths, an 8.4 ft cable with open leads, and a panel mount female connector for a junction box.
Sources: Somfy Sonesse 40 400 Series Databook (Somfy Systems, 7/2018, service.somfy.com) for hardwired 1001636/1001637/1001638; Somfy 400 Series Databook L-0173 (10/2021) for fast connector 1240380/1240381/1240382, extensions and panel mount; somfysystems.com product pages 1240380 and 1240382; Somfy RTS motor programming instructions (somfysystems.com).