Short answer: Somfy marks Glydea ULTRA 1003152, 1003159, 1003151 and 1003158 obsolete and names a direct replacement for each: 1246116, 1246118, 1246115 and 1246117. Match size (35 or 60) and control (RTS or DCT), drop the new head into the existing drive pulley, run one command to record the hard stops, then pair every remote and hub again.
A dead drapery motor on a five-year-old job looks like a quick swap. The callback comes after you leave: the TaHoma scene does nothing, the URTSI II channel is silent, and the client's bedside remote controls the wrong window. The motor was fine. The pairing list left the building with the old head. This guide gives you the part map, the track checks, the swap and the re-pairing order that closes the job in one visit.
Free spec package
Glydea ULTRA motor replacement drawing set

- SMD-01 general notes, sheet index and system limits with sources
- SMD-02 track and bracket detail plus a keep-or-replace parts schedule
- SMD-03 RTS re-pairing riser, DCT RJ12 pinout and DCT cable limits
- SMD-04 three-part guide spec, BOM and retrofit closeout checklist
Match the obsolete part number to the Somfy replacement
Read the label on the old head. Somfy's US product pages mark all four first-generation 10 ft plug Glydea ULTRA motors obsolete and point each one to its successor. The ULTRA 60 RTS 1003159 goes to Glydea ULTRA 60 RTS 1246118. The ULTRA 35 RTS 1003152 goes to Glydea ULTRA 35 RTS 1246116. On dry contact jobs, 1003158 goes to Glydea ULTRA 60 DCT 1246117 and 1003151 goes to Glydea ULTRA 35 DCT 1246115.
The successors keep the numbers an integrator cares about. The Somfy page for 1246118 lists 433.420 MHz RTS, 12 channels, IP 30, 38 dB and a 5-year warranty, the same radio, channel count, rating and noise line the 1003159 page shows. The Drapery Databook rates both new models at 120 V AC with a 10 ft cable and molded NEMA plug.
Do not downsize to save money. The Somfy Drapery Databook rates the ULTRA 35 at 77 lb on up to 32 ft of track and the ULTRA 60 at 132 lb on up to 36 ft. A heavy lined drape that ran on a 60 will stall a 35. Our rule: replace a 60 with a 60 and a 35 with a 35 unless you weigh the fabric.
Confirm the track before you order the motor
The head is the only part you have to change. Somfy lists the Glydea drive pulley 1780945, the high performance 10 mm belt 1782084 and the heavy duty master carrier 1781344 as accessories on the obsolete 1003159 page and on the current 1246118 page. Same pulley, same belt, same carrier family.
Walk the track anyway. A motor replaced on a sagging track comes back as a second callback. The databook sets four limits you can check in five minutes: a maximum of 2 splices, a fixed bend radius of 11.8 in, a minimum curve radius of 118 in, and one bracket at each pulley, one every 24 in, and one on each side of a splice. Missing or cracked brackets get a one touch ceiling bracket 1780907 on straight runs or a swivel ceiling bracket 1780906 on curves, which Somfy recommends for curved and bent tracks.
Bends cut capacity. The databook rates an ULTRA 60 one-way track with one bend at 100 lb up to 32 ft and 77 lb up to 36 ft, and drops a continuous center-opening curve to 113 lb up to 10 ft. Check the fabric against the chart line for the track shape you have, not the straight-track headline.
Swap the head in four moves
Somfy's Glydea Ultra RTS instructions (ref. 5037612B) describe the motor install in three steps: unlock the motor, insert the motor shaft into the drive pulley hole, lock the motor. Pull the old head the same way in reverse. Unplug it first. The motor ships with a grounding plug, and Somfy's instruction says not to change the plug in any way.
- Unplug the old head, unlock it and lift it off the pulley.
- Seat the new head on the same pulley and lock it. The motor can sit on the left or right of the track.
- Plug in. For RTS, pre-program one remote: press Open and Close together until the drapery moves.
- Send one Open or Close command. The motor makes a first run and records the hard stop positions.
Check direction next. Press Open. If the drapery closes, hold my until it moves and the direction flips. Then press PROG on the back of the remote until the drapery moves. That remote is now recorded for good.
Glydea ULTRA replacement limits (Somfy)
- ULTRA 35: 77 lb, 32 ft straight track max. ULTRA 60: 132 lb, 36 ft max.
- Track: 2 splices max, 11.8 in bend radius, 118 in minimum curve radius.
- Brackets: 1 at each pulley, 1 every 24 in, 1 each side of a splice.
- RTS: 433.420 MHz, 12 channels per motor (Somfy product page).
- Speeds: silent 7.5 cm/s; standard 12.5, 15 (default), 17.5 or 20 cm/s.
- DCT runs: Cat5 to 328 ft for 10 motors; 0.75 mm2 to 656 ft for 20 motors.
Re-pair every remote, hub and interface
This is the step that decides whether the job stays closed. Each RTS transmitter, hub channel and interface channel that drove the old head has to be recorded in the new one. Somfy's process: put the motor in programming mode by holding PROG on a remote already recorded until the drapery moves, then press PROG briefly on the next transmitter until the drapery moves again.
Count the transmitters before you pull the old head. A typical drapery has a Situo 5 RTS remote, a wall switch, and one or two system channels: a TaHoma Switch channel for scenes and voice, or a URTSI II channel for Control4, Crestron or Savant. Each of those is one more RTS transmitter to add. The Somfy page lists 12 channels per motor, which covers any sane residential drapery.
Our rule: write the transmitter list on the old head's box before you uninstall it. Remote, wall switch, hub channel number, interface channel number. Re-pair from the list and test each one from its own button, app tile or keypad, not from your service remote.
Need a clean slate on a used head? Somfy's instructions give two resets. Hold the S button with a pin until the drapery moves twice to delete every control point and keep the limits and my position. Hold it until the drapery moves three times to erase control points, sensors, end limits and my.
DCT jobs: re-land the RJ12 and the contact closures
A DCT head takes its commands from dry contacts through an RJ12 port, and the databook lists the control circuit at 3.3 V DC. The RJ12 pinout per the databook: pin 1 open (CCW), pin 3 ground common, pin 5 stop, pin 6 close (CW). Pins 2 and 4 are unused. Re-land the existing control cable on the same pins and the lighting or control system keeps its programming.
The control system does not care that the head changed. It closes the same contacts. Your job is to confirm the cable run still fits the Somfy table: Cat5 or equal to 328 ft with up to 10 motors, or 0.75 mm2 to 656 ft with up to 20 motors. For limits and settings, Somfy names the DCT Limit Setting Tool 9014599 as the preferred method and lists the 8 ft RJ12 cable 9015443 as required with it.
Running SDN on the floor? Somfy lists the RS485 (2-way) module 1871412 for Glydea ULTRA motors. Spec it from the module's own compatibility list and commission it with Set pro, as covered in our Glydea ULTRA DCT on SDN guide.
Commission it and close the ticket
Set the speed the client had. Slide the selector to SILENT for 7.5 cm/s, or to HI-SPEED and pick 12.5, 15, 17.5 or 20 cm/s: hold Open and my/Stop together until the drapery moves, step with Open or Close, confirm with my/Stop. Touch motion ships at high sensitivity. Cycle it through low and off from the same Open and Close programming entry if the client never used it.
Record the my position, test touch motion, then run the drape end to end from every transmitter on your list. Fine-tune an end limit by driving to it, holding Open and Close until the drapery moves, jogging to the new spot and confirming with my/Stop. Write the new part number and install date on the closeout sheet. Somfy backs the replacement with its 5-year warranty.
Take the spec package to your submittal
Glydea ULTRA motor replacement drawing set
- SMD-01 general notes, sheet index and system limits with sources
- SMD-02 track and bracket detail plus a keep-or-replace parts schedule
- SMD-03 RTS re-pairing riser, DCT RJ12 pinout and DCT cable limits
- SMD-04 three-part guide spec, BOM and retrofit closeout checklist
FAQ
Do I need new track to replace an obsolete Glydea ULTRA motor?
No. Somfy lists the same drive pulley 1780945, belt 1782084, master carrier 1781344 and brackets as accessories on the obsolete and the current Glydea ULTRA pages. The motor shaft inserts into the existing drive pulley and locks. Replace a worn pulley, belt or carrier on its own merits.
Will the old RTS remotes work with the new Glydea ULTRA motor?
Yes, after you pair them again. RTS addresses are stored in the motor, so they leave with the old head. Pre-program one remote with Open and Close together, record it with its PROG button, then add every other remote, hub channel and interface channel from that remote.
Can I put a Glydea ULTRA 35 in place of an ULTRA 60?
Only if the drapery and track fit the 35 limits: 77 lb and 32 ft of straight track per the Somfy Drapery Databook. The ULTRA 60 carries 132 lb on up to 36 ft. Bends and curves lower both numbers. Our rule: replace a 60 with a 60.
Do I need the setting tool for a DCT Glydea ULTRA replacement?
Somfy names the Limit Setting Tool 9014599 as the preferred way to program Glydea ULTRA DCT motors and lists the 8 ft RJ12 cable 9015443 as required with it. Plan both on the van before the service call.
Sources: Somfy US product pages for 1003152, 1003159, 1003151, 1003158 (obsolete, replaced by) and 1246118 (technical characteristics, accessories); Somfy Drapery Databook, Glydea ULTRA and Irismo, June 2026 (capacities, track limits, bracket rule, DCT pinout and cable table, control modules); Somfy Glydea Ultra RTS instructions ref. 5037612B (install, commissioning, re-pairing, resets, speeds).
Ryan Towns writes the Somfy Integrator Guides for ShadeMotorsDirect, an authorized Somfy distributor. Questions on a spec or a retrofit: 859-414-6872 or colin@shademotorsdirect.com, 8:00 AM - 7:30 PM ET.