Finish every module, pass the quiz, unlock 10% off
Module 1 of 4
Why a controller
The databook rule that makes the IGC 4n1 necessary. After this module you can explain why two 4-wire motors never share a switch.
3 lessons, then a scenario check.
Shade Motors School · Wired and Networked · 301
Somfy says not to parallel wire its 4-wire motors, so groups run through a controller. Learn what the IGC 4n1 does, its electrical ratings, how presets work, how units daisy chain and which wall station plugs into it.
Pass the quiz to unlock 10% off your first ShadeMotorsDirect order. Your code and certificate arrive by email from Shade Motors School.
You will be able to: Specify IGC 4n1 controllers and wall stations to run a group of 120V 4-wire Somfy motors.
Line-voltage work. 120V motors, switches and wiring must be installed by a licensed electrician, with power off at the breaker. The course explains what to ask for and how to check it.
Inside this course
Finish every module, pass the quiz, unlock 10% off
Module 1 of 4
The databook rule that makes the IGC 4n1 necessary. After this module you can explain why two 4-wire motors never share a switch.
3 lessons, then a scenario check.
Why a controller
Somfy's 500 Series Databook lists "do not parallel wire" for its 4-wire motors. One switch runs one motor; groups go through a controller.
Watch forTwo shades on one switch is the mistake this rule exists to stop.
Why a controller
For a single shade, the Maintained Rocker Switch Kit (1800342) is Somfy's 120V single-channel wired switch.
On the jobTurn the power off at the breaker and follow local code. A licensed electrician makes 120V connections.

Why a controller
The Sonesse 506S2 Standard 4-wire (1001814) has no radio and draws 1.2 A at 120V 60Hz.
ExampleFour of these in a boardroom go on one IGC 4n1.

Check yourself
Hint: Read the databook rule.
No. Somfy says do not parallel wire them. Use an IGC 4n1.
Finish every module, pass the quiz, unlock 10% off
Module 2 of 4
Motors, groups and presets. After this module you can describe the controller to a client.
3 lessons, then a scenario check.
What the IGC 4n1 does
The IGC 4n1 (1811416) powers up to four wired motors with individual and group control, and up to three intermediate positions per motor.
ExampleFour office shades open together or one at a time, with a half-way preset.
What the IGC 4n1 does
Somfy lists up to three intermediate positions, set at 25%, 50% and 75% by default.
On the jobAsk the client which positions they use before you change the defaults.
What the IGC 4n1 does
Somfy rates it at 120V 60Hz, 20 A, about 186 W, IP20, UL listed.
Watch forIP20 means indoors, in a dry location.

Check yourself
Hint: It is in the name.
Up to four.
Finish every module, pass the quiz, unlock 10% off
Module 3 of 4
The electrical figures that shape the circuit. After this module you can plan the feed for one or several units.
3 lessons, then a scenario check.
Power and placement
Somfy lists 120V 60Hz, 20 A and about 186 W for the IGC 4n1, with an IP20 rating and UL listing.
On the jobPlan the circuit with the electrician from these figures.
Power and placement
A 506S2 4-wire draws 1.2 A. Four on one controller is 4.8 A of motor load.
Watch forCheck each motor record for its own current.
Power and placement
IP20 means a dry indoor location. Mount it where it can be serviced.
ExampleAbove an access panel beats behind finished drywall.
Check yourself
Hint: Read the IP rating.
Indoors in a dry location, since it is IP20, and where it can be reached for service.
Finish every module, pass the quiz, unlock 10% off
Module 4 of 4
Wall control for the controller and how to run groups larger than four motors. After this module you can specify stations, daisy chains and the number of IGC 4n1 units for a room or a whole floor of 4-wire shades.
3 lessons, then a scenario check.
Stations and daisy chains
The Single Push-Button Switch Station (1810571) gives UP, STOP and DOWN through a 6-pin modular connector.
On the jobRun the modular cable before drywall.

Stations and daisy chains
Several IGC 4n1 units daisy chain, so one keypad can run all of them.
ExampleEight conference room shades: two units, one keypad.
Stations and daisy chains
Divide the motor count by four and round up.
Watch forFive motors still need two units.
Check yourself
Hint: Divide by four, round up.
Three, daisy chained.
Final quiz
Each question is a real job scenario, one per screen. Stuck? Tap the hint. You see the right answer and why right after you choose. Pass and you get a printable certificate.
Score 80% to unlock 10% off your first ShadeMotorsDirect order.
Question 1 of 10
On the job: Two 4-wire motors on one switch.
Hint: Databook.
Somfy lists do not parallel wire.
Question 2 of 10
On the job: One 4-wire shade needs a switch.
Hint: Single.
1800342 is a single-channel 120V switch.
Question 3 of 10
On the job: You count motors per IGC 4n1.
Hint: Name.
Up to four.
Question 4 of 10
On the job: The client wants preset positions.
Hint: Intermediate.
Somfy lists up to three.
Question 5 of 10
On the job: You read the defaults.
Hint: Quarters.
Somfy lists 25/50/75%.
Question 6 of 10
On the job: You plan the circuit.
Hint: Line voltage.
Somfy lists 120V 60Hz, 20 A.
Question 7 of 10
On the job: The IGC 4n1 is IP20.
Hint: IP20.
IP20 is a dry indoor rating.
Question 8 of 10
On the job: You need a wall station for the IGC.
Hint: Modular plug.
1810571 connects with a 6-pin modular connector.
Question 9 of 10
On the job: Nine shades from one keypad.
Hint: Round up.
9 / 4 rounds up to 3.
Question 10 of 10
On the job: Several units need one keypad.
Hint: Chain.
Somfy lists daisy chain for one keypad.
Almost done
Your score shows on the next screen. If you pass, your certificate and 10% code go to this email. They come from Shade Motors School (school@shademotorsdirect.com). Check Promotions, Updates or Spam if you don't see them.
Parts used in this course