Somfy sells the Simu DMI6 as a wired 120V tubular motor with a manual override, at 60, 80 or 100 Nm and 14 rpm, for heavy awnings and rolling shutters. Learn to size torque and current, plan the larger tube, fit the DMI bracket, crown and drive, and set the limits the way Simu asks.
Pass the quiz to unlock 10% off your first ShadeMotorsDirect order. Your code and certificate arrive by email from Shade Motors School.
You will be able to: Pick, fit and set the right Simu DMI6 120V motor with a hand crank for a heavy awning or shutter.
Line-voltage work. 120V motors, switches and wiring must be installed by a licensed electrician, with power off at the breaker. The course explains what to ask for and how to check it.
Inside this course
Finish every module, pass the quiz, unlock 10% off
Module 1 of 5
You will be able to name the three DMI6 120V refs, read a DMI6 name, and match the motor to the jobs Somfy lists.
4 lessons, then a scenario check.
Meet the Simu DMI6 wired range
Somfy offers the 120V DMI6 at 60, 80 and 100 Nm. All three run at 14 rpm, so torque is the only choice you make.
ExampleA shop that stocks the 60 Nm and the 100 Nm covers both ends of the range. The speed stays the same on each.
Meet the Simu DMI6 wired range
Simu names each DMI6 by family, torque, speed and supply. DMI6 80Nm 14rpm 120V means 80 Nm at 14 rpm on 120V.
On the jobRead the old motor label before you order and match the torque figure in the name.
Meet the Simu DMI6 wired range
Somfy lists two applications on the DMI6 e-cat pages: awning and rolling shutter. Plan another motor family for an interior shade.
Watch forA designer asks for a DMI6 on a large interior roller shade. Point them to a motor Somfy lists for interior window coverings.
Meet the Simu DMI6 wired range
Somfy lists Wired as the embedded technology, so the DMI6 has no radio receiver. Its CMO head takes a manual override for moving the product by hand.
On the jobA shutter client wants a wall switch for daily use and a crank for power cuts. A DMI6 covers both.

Check yourself
Hint: Look at the embedded technology row on the DMI6 page.
Somfy lists the DMI6 as Wired with no receiver, so it needs a wired control point.
Finish every module, pass the quiz, unlock 10% off
Module 2 of 5
You will be able to pick the smallest DMI6 that covers the job, give the electrician the current for each motor, and spot a thermal stop.
4 lessons, then a scenario check.
Size the torque, current and run time
Pick the smallest DMI6 that meets or beats the torque the maker gives you. A 72 Nm job takes the 80 Nm ref.
ExampleThe maker calls for 58 Nm. The 60 Nm ref covers it, so you skip the larger, heavier draw of the 80.
Size the torque, current and run time
Somfy lists 2.5 A for the 60 Nm, 3.4 A for the 80 Nm and 3.8 A for the 100 Nm. Add every motor on a circuit.
On the jobTwo 100 Nm motors share a circuit. Give the electrician 7.6 A, which is 3.8 A twice.
Size the torque, current and run time
Somfy lists a 108 V to 126 V working window for all three refs.
Watch forA long cable run to a shutter box drops the voltage. Measure at the motor lead before you call the motor faulty.
Size the torque, current and run time
Somfy lists a thermal time of 5 min for the 60 and 100 Nm refs and 4 min for the 80 Nm. A drive that trips needs to cool.
Watch forA tech cycles a new shutter over and over and it stops. Wait for the drive to cool before you call it faulty.
Check yourself
Hint: Find the first torque step at or above the target, then read its current.
The 80 Nm ref (2001042), the first step that covers 72 Nm. Somfy lists 3.4 A for it.
Finish every module, pass the quiz, unlock 10% off
Module 3 of 5
You will be able to tell when a job outgrows the DMI5, check the tube for a DMI6, and know the drilling figure for all three refs.
3 lessons, then a scenario check.
DMI5 or DMI6: plan the tube
Somfy lists the 120V DMI5 refs from 10 to 50 Nm. The DMI6 starts at 60 Nm, so a heavier job moves to the larger family.
On the jobA shutter maker calls for 65 Nm. The 50 Nm DMI5 falls short, so you quote the 80 Nm DMI6.
DMI5 or DMI6: plan the tube
Somfy lists a 1.85 in minimum internal diameter for the DMI5 and 2.37 in for the DMI6. Simu's guide gives 47 and 60 for the same pair.
Watch forAn old DMI5 tube measures 1.9 in inside. It fits a DMI5 but sits under 2.37 in, so plan a new tube.
DMI5 or DMI6: plan the tube
All three DMI6 refs list a 2.26 in external diameter and a 26.06 in riveting position distance.
ExampleYou upsize a 60 Nm to a 100 Nm in the same tube. The rivet line stays put.
Check yourself
Hint: Compare the minimum tube size for each family.
The tube. Somfy lists a 2.37 in minimum internal diameter for the DMI6, larger than the 1.85 in it lists for the DMI5.
Finish every module, pass the quiz, unlock 10% off
Module 4 of 5
You will be able to order a DMI bracket Somfy lists for the DMI6 and pick the crown and drive pair named for your tube.
5 lessons, then a scenario check.
Fit the head, bracket, crown and drive
Somfy lists the DMI6 head type as CMO. Pick the bracket from the DMI brackets on its accessory list.
Watch forThe truck carries a star bracket from an LT50 job. Leave it there and fit a DMI bracket.
Fit the head, bracket, crown and drive
The 9706034 DMI Bracket is a steel plate, 3.94 x 3.94 in. Its page lists all three DMI6 refs.
ExampleA shutter box has a flat side wall. The square plate gives you a fixed face to bolt to.

Fit the head, bracket, crown and drive
Somfy notes that only 3 fixing screws attach the 9706034 to the end product, with fixings 3.39 in between centers.
On the jobMark the 3.39 in centers on the box wall before you drill, then set the plate.

Fit the head, bracket, crown and drive
The DMI6 list carries crowns and drives for seven tube profiles, from 60 mm round to 94 mm round. Order the pair named for your tube.
On the jobMeasure the tube profile on site, then pick the crown and drive with that size in the name.
Fit the head, bracket, crown and drive
Somfy describes the 9012950 as an aluminum drive wheel, 60 mm round, for T5 and T6 operators. Its page lists all three DMI6 refs.
ExampleA 60 mm round tube on an 80 Nm job takes the 9012950 drive.

Check yourself
Hint: Start from the head type Somfy lists for the DMI6.
The 9706034 DMI bracket. Somfy lists a CMO head on the DMI6, and the 9706034 page lists the 100 Nm ref.
Finish every module, pass the quiz, unlock 10% off
Module 5 of 5
You will be able to plan the crank, set both end limits at the head, recheck them after manual use, and wire one control point per motor.
5 lessons, then a scenario check.
Override, limits and safe wiring
The DMI6 list carries 7 mm hex extension shafts at 220 mm (9420657) and 330 mm (9420659), plus a 7 mm hex to 8 mm square joint.
On the jobMeasure from the head to where the crank will sit, then order the shaft length that reaches it.

Override, limits and safe wiring
Simu says the motor stays powered during the emergency maneuver and the end limits may shift. Check both limits after any hand use.
Watch forA client cranked the awning in during an outage. Run it end to end once power returns.
Override, limits and safe wiring
Press up on the control point and turn the upper setting screw. Then press down and turn the lower setting screw.
On the jobA shutter stops short of the top. Run it up, then turn the upper screw until it reaches the stop you want.
Override, limits and safe wiring
Simu asks you to check that several motors are not connected to the same control point. Give each DMI6 its own.
Watch forA client wants two shutters on one switch. Fit a control point per motor and let the electrician wire each one.
Override, limits and safe wiring
Somfy lists a white 4-wire VVF cable, 8.2 ft, stripped ends. Simu says it cannot be removed, so a damaged cable goes back to After-Sales.
Watch forA fabricator nicks the lead while fitting the box. Send the drive back to After-Sales. Do not splice a new cable on.
Check yourself
Hint: Recall what Simu says the crank can do to the end positions.
Run the shutter end to end and check both limits, since Simu says the end limits may shift after the emergency maneuver.
Final quiz
Each question is a real job scenario, one per screen. Stuck? Tap the hint. You see the right answer and why right after you choose. Pass and you get a printable certificate.
Score 80% to unlock 10% off your first ShadeMotorsDirect order.
Question 1 of 10
On the job: A client wants a DMI6 on a large interior roller shade in a living room.
Hint: Recall the applications Somfy lists on the DMI6 pages.
Somfy lists two applications for the DMI6 refs: awning and rolling shutter.
Question 2 of 10
On the job: A homeowner plans to pair a handheld radio remote straight to a new DMI6.
Hint: Check the embedded technology row.
Somfy lists Wired as the embedded technology, so the DMI6 has no radio receiver.
Question 3 of 10
On the job: The shutter maker calls for 72 Nm.
Hint: Find the first torque step at or above the target.
80 Nm is the smallest DMI6 step that covers 72 Nm.
Question 4 of 10
On the job: Two 100 Nm DMI6 motors will share one circuit.
Hint: Add the rated current Somfy lists for each motor.
Somfy lists 3.8 A for the 100 Nm ref, so two motors draw 7.6 A.
Question 5 of 10
On the job: A new 80 Nm shutter stops after the tech runs it up and down many times in a row.
Hint: Think about what repeated runs do to a motor.
Simu says a drive that stops may be in thermal protection and needs to cool; Somfy lists a 4 min thermal time for the 80 Nm.
Question 6 of 10
On the job: A 50 Nm DMI5 awning now needs 70 Nm, and the existing tube measures 1.9 in inside.
Hint: Compare the tube to the DMI6 minimum.
Somfy lists a 2.37 in minimum internal diameter for the DMI6, so a 1.9 in tube must be replaced.
Question 7 of 10
On the job: You upsize a 60 Nm DMI6 to the 100 Nm in the same tube.
Hint: Recall what changes, and what stays the same, across the three DMI6 bodies.
Somfy lists the same 2.26 in diameter and 26.06 in riveting position distance on all three refs.
Question 8 of 10
On the job: The installer brings an LT50 star bracket for a 100 Nm DMI6.
Hint: Check the head type Somfy lists for the DMI6.
Somfy lists a CMO head on the DMI6 and DMI brackets such as 9706034 on its accessory list.
Question 9 of 10
On the job: The job uses a 60 mm round tube on an 80 Nm DMI6.
Hint: Start from the tube profile you measured.
Somfy describes 9012950 as a 60 mm round aluminum drive wheel for T5 and T6, and its page lists the DMI6 refs.
Question 10 of 10
On the job: A client cranked the shutter closed during a power cut.
Hint: Recall what Simu says about the limits after manual use.
Simu says the end limits may shift after the emergency maneuver, so check them again.